Research on Michelson interference refractive index sensing technique based on double-core microfiber
Article
Figures
Metrics
Preview PDF
Reference
Related
Cited by
Materials
Abstract:
We propose a novel refractive index sensor based on Michelson interferometer by using double-core microfiber. Through the reflection of the end and taper of double-core fiber (DCF), the Michelson interference spectrum is formed. Owing to the structure characteristic of double-core microfiber, this interferometer can achieve the measurement of refractive index (RI) and temperature. The experimental results show that the refractive index sensitivity of the interferometer is 2 377.80 nm/RIU at the diameter of the taper waist of 8.76 µm. In the temperature ranges from 30 °C to 60 °C, the temperature sensitivity is 0.070 48 nm/°C. This sensor has the advantage of high refractive index sensitivity.
ZHANG Hongling, ZHANG Fang, CONG Bitong, QI Yuefeng. Research on Michelson interference refractive index sensing technique based on double-core microfiber[J]. Optoelectronics Letters,2021,17(9):513-517