Optical transient waveform monitoring based on cross-gain modulation in semiconductor optical amplifier
Article
Figures
Metrics
Preview PDF
Reference
Related
Cited by
Materials
Abstract:
An all-optical transient waveform equivalent time sampling system based on cross-gain modulation (XGM) in semiconductor optical amplifier (SOA) is presented. A noisy SOA dynamic model and PIN equivalent circuit function are employed for system evaluating. The results show this SOA-XGM sampler with subtracting postprocessing can achieve picosecond sampling window. The shape of sampling window can be adjusted by SOA bias current and amplitude of control pulse. Compared with amplified spontaneous emission (ASE) noise of SOA and thermal noise in PIN, the jitter of sampling control pulse causes most sampling error. Simulations show that this SOA-XGM sampler can be a capable candidate for transient waveform sampling.
Keywords:
Project Supported:
This work has been supported by the National Natural Science Foundation of China (No.61077068), and the Science and Technology Commission
Yang Yi, Xiao Zhong-yin, Liu Jian-sheng, Wang Guan-jun. Optical transient waveform monitoring based on cross-gain modulation in semiconductor optical amplifier[J]. Optoelectronics Letters,2012,8(1):40-42