Thermal lens measurement of a LD end-pumped Nd: GdVO4 laser with stable resonator by a slit-scanning method
DOI:
Author:
Affiliation:

Clc Number:

TN248

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    A simply method to measure the thermal focal length of a LD end-pumped Nd.GdVO4 solid state laser with a stable resonator is presented. By scanning a slit across the field with expression of multi-mode Gaussian distribution behind the output mirror of lasers, the radius and the M^2 factor describing the quality of beam can be measured. The waists of the multi-mode field and the TEM00 mode can be deduced according to the law of multi-mode Gassian beam propagation. Based on the ABOD matrix theory of a stable resonator,the thermal focal length of the active medium can be easily obtained. The thermal focal length of a LD end-pumped Nd. GdVO~ laser has been measured and the experimental results agree with the theoretically analyzed values.

    Reference
    Related
    Cited by
Get Citation

Jing Zou, Sheng-zhi Zhao, Ke-jian Yang, Gui-qiu Li, Peng Song. Thermal lens measurement of a LD end-pumped Nd: GdVO4 laser with stable resonator by a slit-scanning method[J]. Optoelectronics Letters,2005,1(2):113-116